For jointed precast concrete pavements, this study suggests a novel demountable dowel bar system made of glass fiber reinforced polymer (GFRP). The conventional steel dowel systems have limited reuse, corrosion, and concentrated stress. On the other hand, the suggested solution features a stainless steel sleeve that accommodates the GFRP bar, providing both removability and durability. Under monotonic loading circumstances, four slab specimens measuring 300 mm, 400 mm, and 800 mm in width were put to the test. The findings demonstrated that, in contrast to specimens with traditional steel dowels, those with GFRP dowels had distinct failure processes. The suggested system's potential application in modular pavement systems was indicated by its encouraging load-bearing capability and flexibility.
Al-Shrifi et al. (Thu,) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: