PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
August 20, 2009Cardiology in the Young34 citations

Reliability of echocardiographic measurements of left cardiac structures in healthy children

View Full Paper
MGMiranda GeelhoedSSSonja P. E. SnijdersVKVeronica E. Kleyburg-Linkers

Structured PICO

P
Population
28 healthy children, median age 7.5 years (IQR 3 to 11 years)
I
Intervention
Echocardiographic measurements of left cardiac structures (aortic root, left atrium, left ventricular end-diastolic structure, ventricular end-diastolic septal thickness, left ventricular posterior wall)
O
Outcome
Intraobserver and interobserver reliability (intraclass correlation coefficients and Bland-Altman limits of agreement)surrogate

Echocardiographic measurements of left cardiac structures in children demonstrate high intraobserver and interobserver reliability, supporting their use in clinical and epidemiological research.

Abstract

BACKGROUND: Echocardiographic measurements are widely used as outcomes of different studies. The aim of this study was to assess intraobserver and interobserver reliability of echocardiographic measurements in healthy children. MATERIALS AND METHODS: We studied 28 children, with a median age of 7.5 years, and inter-quartile range from 3 to 11 years. Intraobserver and interobserver reliability were assessed by repeated measurements of the diameters of the aortic root, the left atrium, and left ventricular end-diastolic structure. We also measured the ventricular end-diastolic septal thickness and the end-diastolic thickness of the left ventricular posterior wall. We calculated intraclass correlation coefficients, with corresponding 95% confidence intervals, and computed Bland and Altman plots, permitting us to derive limits of agreement plus or minus 2 standard deviations for the mean differences in cardiac measurements. RESULTS: We found high intraobserver and interobserver intraclass correlation coefficient, ranging from 0.91 for ventricular septal thickness, with 95% confidence intervals from 0.78 to 0.96, to 0.99 for the diameter of the aortic root, 95% confidence interval from 0.97 to 1.00. Limits of agreement in the Bland and Altman plots ranged from zero millimetres for left ventricular end-diastolic posterior wall thickness to 1.60 millimeters (6.3%) for left atrial diameter. CONCLUSIONS: Our study demonstrated good repeatability and reproducibility for ultrasonic measurements of left cardiac structures in children, showing that values obtained for measurement of these structures in both clinical and epidemiological research projects can be confidently accepted.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Geelhoed et al. (2009) studied this question.

synapsesocial.com/papers/6a7f06cd8ba53d470169a72ahttps://doi.org/10.1017/s1047951109990862
Ask AI
Helpful
Bookmark
Share
View Full Paper