Novel method estimates ionizing radiation dose and exposure time using the γ-H2AX assay, suggesting improvements in retrospective dosimetry.
Accurately estimating the radiation dose received by an individual is essential for evaluating potential damage caused by exposure to ionizing radiation. Most retrospective dosimetry methods require the time since exposure to be known and rely on calibration curves specific to that time point. In this work, we introduce a novel method tailored to the γ-H2AX assay, which is a protein-based biomarker for radiation exposure, that enables the estimation of both the radiation dose and the time of exposure within a plausible post-exposure interval. Specifically, we extend calibration curves available at two distinct time points by incorporating the biological decay of foci, resulting in a model that captures the joint dependence of foci count on both dose and time. We demonstrate the applicability of this approach using both real-world and simulated data.
No takes yet. Share an insight, caveat, or question.
Cai et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: