Automated system quantifies HER2 gene amplification in images, suggesting it aids pathologists efficiently.
The evaluation of erb-b2 receptor tyrosine kinase 2 (ERBB2 or HER2) gene amplification status through Dual in Situ Hybridization (DISH) currently relies on manual assessment by pathologists. There are several deep learning-based algorithms for H&E or ISH analysis. However, DISH analysis tools are still lacking. We developed a fully automated deep learning-based quantification system to assist pathologists in identifying the most relevant cells throughout the entire DISH image. In the comparison between pathologists and the auto-quantification system, the overall percentage agreement (OPA) by case was 88. 9% (80/90). These results demonstrate that each image, with a processing time of approximately 1 minute, achieves similar results compared to pathologists’ assessments, while the manual procedure will take 10-20 times longer to examine the same specimen. This approach offers a versatile system for bright-field HER2 DISH image analysis. The system provides faster, cheaper, standardized, and versatile diagnostic tools to aid pathologists in the HER2 DISH diagnostic process.
No takes yet. Share an insight, caveat, or question.
Huang et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: