Answers are grounded in this paper and cite their sources.
Numerical modeling shows cooling rate improvements in 304L steel during tungsten inert gas welding, suggesting copper backup plates help reduce residual stress.
In this research work, finite element method (FEM)‐based model is developed to investigate the influence of heat sink during tungsten inert gas (TIG) welding of 304L steel plate. The effect of copper backing plates is being discussed with heating and cooling by considering with and without backup plates in the FEM‐based model in the SYSWELD software. The results reveal that the cooling rate is improved, and there is a drop to 200 °C temperature due to the heat sink. Numerical modeling discusses the significant variations in cooling rate during TIG welding with and without a heat sink. Two different experiments are conducted with and without a copper backup plate. Hardness, residual stress, and distortion in the weld plate are measured for each case. The residual stress and distortion using FEM‐based calculation are predicted and validated with experimentally measured values. Maximum distortion is observed at the corner with a value of 3.48 mm in an upward direction. Comparison of with and without backup plate results shows that the copper plate is not so effective; only a 5% difference is observed for distortion in the weld plate, but it reduces the residual stress up to 25 MPa values.
No takes yet. Share an insight, caveat, or question.
Zubairuddin et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: