Tests reveal that diamond detectors provide reliable spectroscopic information at high neutron fluxes, suggesting utility in nuclear physics studies.
We have tested the performance of spectroscopic single-crystal Chemical Vapor-Deposited (sCVD) diamond detectors with radioactive sources and with a pulsed deuterium-tritium neutron generator. The tests demonstrate that the detectors could provide good timing and spectroscopic information at high neutron fluxes. The spectroscopic information can be obtained at a 14 MeV neutron rate as high as 1010 n/cm2/s, despite some limitations associated with pulse character of the used neutron generator. Monte-Carlo simulations were performed in order to achieve better understanding of neutron interaction with the detector material. Possible applications for the use of the detectors at Soreq Applied Research Accelerator Facility (SARAF) are considered. The detectors could be used as reliable neutron rate monitors in the vicinity of a strong accelerator-based source of energetic neutrons. The detectors could also be utilized as time-of-flight tagging counters in nuclear physics experiments under condition of high neutron fluxes during short beam pulses. In particular, measurement of the 12C(n,n′)3α cross-section is discussed.
No takes yet. Share an insight, caveat, or question.
Weissman et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: