Plasma-activated solution demonstrates effective disinfection against SARS-CoV-2 in subzero conditions, indicating new hygiene methods.
Cold-chain logistics is a significant cross-regional transmission pathway for SARS-CoV-2, Staphylococcus aureus, and other microorganisms. In addition, hygiene and safety assurance in extreme low-temperature environments have become an essential requirement across multiple fields (polar research, high-altitude meteorological stations, mountaineering rescue et al.). In this study, plasma-activated gas was used to activate a high-concentration CaCl2 solution (which remains unfrozen at -40°C) to prepare plasma-activated subzero-temperature disinfectant for subzero-temperature disinfection. The plasma-activated subzero-temperature disinfectant achieves a strong and sustained disinfection effect at -40°C, comparable to commercially available subzero-temperature disinfectants, while demonstrating superior subzero-temperature stability and causing less damage to goods. The disinfection efficacy is attributed to the combined action of a low pH acidic environment and various aqueous reactive species. This research expands the application of plasma subzero-temperature disinfection technology, playing an important role in the development of subzero-temperature disinfection technologies and the control of infectious disease transmission.