This analysis shows torque pulsation and torsional resonance effects on shaft cracking in pumps, highlighting fatigue risks.
To investigate the mechanism of shaft crack faults in a power plant’s condensate pump following a change to variable frequency operation, wireless strain testing technology was employed to measure torque pulsation during the start-stop process of the pump as a function of speed. A finite element model of the pump was developed, and the torsional natural frequencies of the shaft were calculated. When a motor operates in variable frequency mode, numerous harmonic components are introduced into the torque. At specific speeds, one of the harmonic frequencies of the torque aligns with the natural frequency of a torsional vibration mode, inducing torsional resonance. Under these conditions, the motor torque experiences significant pulsation, which can readily cause fatigue damage to the shaft. When the pump operates in variable frequency drive mode, its torsional fatigue strength must be verified.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: