Comparison of computerized algorithms and expert assessments in antepartum fetal monitoring reveals inconsistencies, suggesting improvements are necessary.
Background: Cardiotocography (CTG) is widely used for antepartum and intrapartum fetal monitoring, yet its interpretation remains subjective and under-evaluated. In contrast to intrapartum CTG, there are few formal guidelines for antepartum interpretation, and the reliability of clinician assessment is poorly understood. Computerised methods offer a supplementary, standardised assessment, however their agreement with expert human interpretation has not been systematically evaluated. Methods: Five senior clinicians with expertise in fetal monitoring independently analysed 105 15-minute fetal heart rate (FHR) segments using a structured web-based software. For each segment, participants identified the baseline, accelerations and decelerations and categorised variability. Inter-observer agreement was assessed using intraclass correlation (ICC) for baselines and Fleiss' Kappa; for variability. Sensitivity and positive predictive value (PPV) for acceleration and deceleration detection were calculated relative to majority-voted results. DR output was compared against the same consensus annotations. Findings: Baseline agreement was excellent among participants (ICC = 1.0, 95% CI 1.00 - 1.00). Variability classifications showed only moderate concordance (Fleiss' Kappa; = 0.39, 95% CI -0.01 - 0.56). Detection of accelerations and decelerations varied across clinicians (sensitivity 39.2 - 97.2%, PPV 39.7 - 91.3%). The DR system showed good agreement for accelerations (sensitivity = 64.8%, 95% CI 57.1 - 72.1%; PPV = 85.0%, 95% CI 79.5 - 89.8%) but poor agreement for decelerations (sensitivity = 50.0%, 95% CI 14.3 - 75.0%; PPV = 20.0%, 95% CI 4.2 - 39.1%). DR-classified variability showed minimal agreement with clinical ratings (Fleiss' Kappa; = 0.002, 95% CI -0.007 - 0.027). Interpretation: Antepartum CTG interpretation remains inconsistent for decelerations and variability. While baseline assessment is robust, current clinical and algorithmic approaches show limited agreement for more ambiguous patterns. These findings support the need for updated training and refined algorithms to improve reliability in antepartum fetal surveillance.
No takes yet. Share an insight, caveat, or question.
Tolladay et al. (2025) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: