Answers are grounded in this paper and cite their sources.
Randomized trial reveals no significant difference in first-attempt success rates for neonatal venous cannulation, suggesting other factors play a role.
Introduction: Peripheral venous cannulation is an essential procedure in neonatal intensive care units (NICUs) but is often associated with high failure rates. Near-infrared vein visualization devices may enhance vein identification and reduce the number of attempts; however, evidence in neonatal populations remains limited. This study aimed to compare the first-attempt success rates of peripheral venous cannulation using a vein transillumination device versus the standard method in neonates with prior punctures. Secondary analyses explored patient- and performer-related factors associated with successful cannulation. Methodology: This study conducted a prospective, randomized controlled trial from October 2022 to January 2024 in the NICU at Hospital Sultan Abdul Aziz Shah, Universiti Putra Malaysia. Only neonates of ≥ 35 weeks of gestation requiring venous access with at least one prior venipuncture were enrolled. The participants were randomized into standard (control) and AccuVein AV500-assisted (intervention) cannulation groups. All procedures were performed by 14 trained medical officers. First-attempt success was documented as the primary outcome, while secondary outcomes included associations with patient, performer, and procedural factors. Results: A total of 120 neonates were enrolled (60 per group). The overall first-attempt peripheral venous cannulation success rate was 47 (39.2%). No significant differences were observed between the control (21, 35%) and the intervention (26, 43.3%) groups (P > 0.05). Vein palpability was notably associated with cannulation success (odds ratio (OR) 7.86, 95% confidence interval (CI): 2.22-27.85, P = 0.001). Right-sided cannulation was also linked to improved cannulation success (OR 3.44; 95% CI: 1.15-10.32, P = 0.028). Conversely, four or more previous punctures reduced the likelihood of successful peripheral venous cannulation (OR 0.30; 95% CI: 0.09-0.99, P = 0.048). Conclusions: Vein transillumination did not significantly improve the first-attempt peripheral venous cannulation success rate. However, vein palpability, fewer prior punctures, and right-sided cannulation were associated with superior outcomes.
No takes yet. Share an insight, caveat, or question.
Zainudin et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: