Systematic review and meta-analysis shows increased locoregional recurrence risk in patients with higher mammographic breast density.
Understanding locoregional recurrence (LRR) risk is important in breast cancer, as it relates directly to breast cancer-associated mortality. Individualised LRR risk estimation should inform treatment and surveillance strategies. Increased mammographic breast density has been identified as a risk factor for the development of breast cancer. However, the precise relationship between mammographic density and breast cancer LRR remains unclear. To perform a systematic review and relative risk meta-analysis to explore the assocation between breast mammographic density and breast cancer LRR. A systematic review was performed as per PRISMA guidelines. Mammographic breast density (MBD) was classified as BI-RADs A-B (breast density < 50%, predominately fatty or scattered areas of fibroglandular density) or BI-RADs C-D breast density > 50%, heterogeneously dense or extremely dense). A meta-anlysis was performed using Meta-Disc and Statsdirect 2.8.0. Seven studies published between 2004 and 2023 met the inclusion criteria, comprising 3008 patients with reported mammographic breast density (MBD) (age range: 20–94 years). Overall, 59.1% (1779/3008) were classified as low MBD (BI-RADS A-B) and 40.9% (1229/3008) were classified as high MBD (BI-RADS C-D). Of these patients, 68.9% (2073/3008) were treated for invasive breast carcinoma and 31.1% had ductal carcinoma in-situ (DCIS). Breast-conserving surgery (BCS) was performed in 71.1% (2139/3008) of patients, mastectomy was performed in 28.2% (850/3008),. The median follow-up was 94.1 months, and the overall LRR rate was 12.8% (386/3008). Five of the seven studies reported a correlation between BI-RADs C-D and the development of LRR. LRR rates were lower in patients with low mammographic breast density (9.9% for BI-RADS A-B (177/1779)) compared to those with higher mammogaphic breast density (17.0% for BI-RADs C-D. (209/1229)) [P < 0.001, Chi Square]. BI-RADS C-D density on mammography was associated with an increased risk of locoregional recurrence (pooled relative risk 1.41; 95% confidence interval 1.17 to 1.70). Increased mammographic breast density may be associated with an increased risk of LRR. Multidisciplinary team discussions should consider MBD as a potential prognostic factor in when considering surveillance and locoregional control after breast cancer treatment.
No takes yet. Share an insight, caveat, or question.
Nolan et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: