Experimental analysis reveals tensile strengths of 283 and 244 MPa in SiC composite pipes, indicating their potential in nuclear power devices.
The axial and ring tensile strengths of experimental specimens of SiC / SiC composite pipes under normal conditions have been studied. The specimens were made from a three-dimensional Hi-Nicalon Type S woven fiber frame with an interfacial layer of pyrolytic carbon and a SiC matrix obtained by the PIP and CVD methods. It has been established that the failure mechanism of the SiC / SiC composite is quasi-plastic. The axial and ring tensile strengths were 283 and 244 MPa, respectively.
No takes yet. Share an insight, caveat, or question.
Макаров et al. (2023) studied this question.