Key result
Ischaemic ECG changes on exercise stress testing yield ~86% diagnostic accuracy for CMD.
Why the study?
Does exercise stress testing accurately diagnose coronary microvascular dysfunction in patients with angina with non-obstructive coronary artery disease?
Cohort (n=117)
Yes
Does exercise stress testing accurately diagnose coronary microvascular dysfunction in patients with angina with non-obstructive coronary artery disease?
Ischaemic ECG changes during exercise stress testing provide excellent diagnostic accuracy for identifying coronary microvascular dysfunction, particularly the structural endotype, in patients with ANOCA.
Coronary microvascular dysfunction (CMD) is common among patients with angina with non-obstructive coronary artery disease (ANOCA) and leads to poorer clinical outcomes. Exercise stress testing (EST) was shown to have a high specificity for detecting CMD. However, the relationship between diagnosing CMD using different invasive physiological parameters and thresholds and the association between EST findings and the endotype of CMD remains unknown. This multicentre, prospective cohort study enrolled 117 patients with ANOCA who underwent EST prior to invasive coronary angiography with functional assessment to measure coronary flow reserve (CFR), the index of microvascular resistance (IMR) and microvascular resistance reserve (MRR)=(CFR/FFR)×(Pa rest/Pa hyper). CMD was classified using multiple criteria, including MRR <3.0, CFR <2.5 and CFR <2.0 or IMR ≥25. Diagnostic sensitivity and specificity and the accuracy of EST findings (exercise-induced chest discomfort, ischaemic ECG changes and exercise intolerance) for diagnosing CMD were assessed. The prevalence of CMD was similar under all three definitions. However, structural CMD was more common using MRR <3.0. Ischaemic ECG changes during EST showed an excellent diagnostic accuracy of 86.3% (78.7-92.0%) for detecting CMD, with a sensitivity and specificity of 86.2% (68.3-96.1%) and 86.4% (77.4-92.8%), respectively. Exercise-induced chest discomfort also had a good diagnostic accuracy of 76.1% (95% CI 67.3% to 83.5%); however, it offered no additional value when added to ischaemic ECG changes. EST preferentially identified structural CMD, while functional CMD was more frequently missed. Ischaemic ECG changes during EST performed immediately before invasive functional assessment demonstrated excellent diagnostic accuracy for identifying patients with CMD, particularly the structural endotype. NCT05841485.
No takes yet. Share an insight, caveat, or question.
Tsai et al. (2025) conducted a cohort in Angina with non-obstructive coronary artery disease (ANOCA) (n=117). Ischaemic ECG changes during exercise stress testing was evaluated on Diagnostic accuracy for detecting coronary microvascular dysfunction (CMD) (95% CI 78.7-92.0). Ischaemic ECG changes during exercise stress testing demonstrated an excellent diagnostic accuracy of 86.3% (95% CI 78.7-92.0%) for detecting coronary microvascular dysfunction.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: