September 5, 2025Jurnal Ilmiah Teknik Sipil0 citationsOpen Access

Bearing Capacity and Settlement Analysis of Drilled Pile Foundation at the Asn-4 Ikn Apartment Construction Project

View Full Paper
MAMade Dodiek Wirya ArdanaUdayana UniversityIPI Made Aryatirta PredanaUdayana UniversityNDNi Ketut Aprilia Kartiana DewiUdayana University

Key Points

  • Bearing capacity is essential for preventing settlement in foundations under load, which can undermine structural integrity.
  • Ultimate bearing capacities measured were 1076,820 tons using Reese and Wright, and 727 tons from the PDA Test.
  • The finite element method, applied through PLAXIS 2D, provided key insights into settlement estimates crucial for planning.
  • Significant variances were found in settlement values, where the empirical method indicated 10,082 mm, highlighting the need for accurate testing.

Abstract

The relocation of the capital city requires the development of various essential infrastructures to support the functions of the National Capital. ASN-4 IKN Apartment is one of the vertical housing projects that implements land efficiency by constructing high-rise buildings. A thorough analysis of foundation bearing capacity and settlement is necessary, given the unique soil conditions and the lack of previous research in the area. If the foundation does not have sufficient bearing capacity, it may lead to settlement due to the loads applied above it. Therefore, both analyses are crucial during the planning process and should be monitored during implementation through load testing on drilled piles to obtain values for bearing capacity and settlement. This analysis aims to calculate and compare the bearing capacity and settlement of the foundation using analytical methods, the finite element method with the assistance of PLAXIS 2D software, and field load testing through the PDA Test. The ultimate bearing capacity results obtained from the Reese and Wright method are 1076,820 tons, with PLAXIS 2D software 805,576 tons, and from the PDA Test 727 tons. The percentage comparison of bearing capacity values between the Reese and Wright method and the finite element method against the PDA Test are 48,118% and 10,808%. Meanwhile, the settlement values using the empirical method are 10,082 mm, with PLAXIS 2D software 2,742 mm, and from the PDA Test 2,3 mm. The percentage comparison of settlement values between the empirical method and the finite element method against the PDA Test are 1,070% and 0,061%.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Ardana et al. (2025) studied this question.

synapsesocial.com/papers/68bb3a492b87ece8dc9556d3https://doi.org/10.24843/jits.2024.v29.i01.p10
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Comparative Analysis of the Support Capacity and Settlement of Bored Pile Foundations Using Manual Methods and Allpile Software: Case Study2025
  2. 2Bearing Capacity and Settlement of Bored Pile Foundation Based On Spt Test Data Aand CPT Test2024
  3. 3Analysis of Borepile Foundation Bearing Capacity in Building Construction Projects with Pile Driving Analyzer Test2025
  4. 4Analysis Of The Bearing Capacity Of The Boredpile Foundation In The Advanced Construction Project Of Class Iia Prison Pematang Siantar Using Analytical Method And Finite Element Method With Plaxis 2D2025
  5. 5ANALYSIS OF THE EFFECT OF CROSS-SECTIONAL ON THE BEARING CAPACITY AND SETTLEMENT OF PILE FOUNDATION FOR THE SCADA BUILDING2025