Automated process generates 3D resection masks in MRI space, indicating improved accuracy in epilepsy surgery.
MRI-based delineation of brain tissue removed by epilepsy surgery can be challenging due to post-operative brain shift. In consequence, most studies use manual approaches which are prohibitively time-consuming for large sample sizes, require expertise, and can be prone to errors. We propose RAMPS (Resections And Masks in Preoperative Space), an automated pipeline to generate a 3D resection mask of pre-operative tissue. Our pipeline leverages existing software including FreeSurfer, SynthStrip, Sythnseg and ANTs to generate a mask in the same space as the patient’s pre-operative T1 weighted MRI. We compare our automated masks against manually drawn masks and two other existing pipelines (Epic-CHOP and ResectVol). Comparing to manual masks (N=87), RAMPS achieved a median(IQR) dice similarity of 0.86(0.078) in temporal lobe resections, and 0.72(0.32) in extratemporal resections. In comparison to other pipelines, RAMPS had higher dice similarities (N=62) (RAMPS:0.86, Epic-CHOP:0.72, ResectVol:0.72). We release a user-friendly, easy to use pipeline, RAMPS, open source for accurate delineation of resected tissue.
No takes yet. Share an insight, caveat, or question.
Simpson et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: