Experimental analysis reveals leakage characteristics and sealing efficacy in oil-gas systems, suggesting improvements.
In this paper, we aim to study the oil–gas two-phase flow characteristics, leakage characteristics, and critical oil sealing characteristics of the bearing cavity sealing system of aero-engine bearings. For this purpose, the unsteady solution models of the conventional bearing cavity sealing system and the graphite with oil-return groove bearing cavity sealing system based on the Euler–Euler two-phase flow method were established. The experimental device for the oil–gas two-phase flow for the bearing cavity was designed and constructed. Thus, the oil–gas two-phase oil sealing characteristics of both systems under different structural and working condition parameters were studied. The results show that the change in the sealing length does not affect the leakage of lubricating oil for the conventional bearing cavity sealing system. It was observed that the higher the rotate speed is, the greater the oil leakage and the greater the critical sealing pressure difference. The graphite with oil-return groove structure can significantly reduce the leakage of lubricating oil and the critical sealing pressure difference. The increase in the length and number of oil-return groove can effectively reduce the leakage of lubricating oil. The width of the oil-return groove has no obvious effect on the sealing and leakage characteristics of the lubricating oil.
No takes yet. Share an insight, caveat, or question.
Ren et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: