This research demonstrates mitigation of leakage current and common-mode voltage in hybrid inverters, indicating improved efficiency.
Three‐phase transformerless inverter configurations are widely used in solar photovoltaic (PV) systems due to their high‐efficiency power transfer capabilities to the grid. However, the main issue in transformerless grid‐connected inverters is the suppression of leakage current (LC), which arises from parasitic capacitances and is worsened by the absence of galvanic isolation. To reduce the LC with the grid standards, we need to maintain the constant common‐mode voltage (CMV). Additionally, this poses a challenge to the reactive power injection capability of these inverters under varying grid voltage and power factor conditions. Various transformerless configurations have been established, utilising advanced modulation techniques to address LC suppression and CMV stabilisation. However, these designs often exhibit significant switching losses and inconsistent reactive power performance, limiting their efficiency and reliability in practical applications. To overcome these limitations, hybrid inverter topologies have been approached with modified discontinuous pulse width modulation (MDPWM) techniques. In this research, theoretical modelling and simulation studies are performed using MATLAB/Simulink to evaluate the performance of different hybrid transformerless configurations with proposed MDPWM in reducing switching losses, ensuring CMV stability, minimising device stress and enhancing reactive power handling in PV‐fed systems. Additionally, the most effective topology is identified and validated through experimental analysis, demonstrating its superior performance with reduced LC and less variation in CMV. Summary Four hybrid transformerless inverter configurations are compared regarding common mode voltage, leakage current, switching losses and reactive power for grid‐tied PV systems. A modified discontinuous PWM (MDPWM) technique has been approached for all four configurations to reduce switching losses and stabilise CMV across all designs. The study analyses voltage and thermal stress in NPC versus non‐NPC hybrid topologies to enhance inverter reliability. RTDS experiments validate the system's performance in managing current, CMV and leakage current dynamically, supporting real‐world use.
No takes yet. Share an insight, caveat, or question.
Kumar et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: