This analysis shows improved joint angle accuracy in upper limb movements using inverse kinematics, indicating potential for daily living tasks.
This study evaluates the accuracy of single camera markerless motion capture (SCMoCap) using Microsoft's Azure Kinect, enhanced with inverse kinematics (IK) via OpenSim, for upper limb movement analysis. Twelve healthy adults performed ten upper-limb tasks, recorded simultaneously by OptiTrack (marker-based) and Azure Kinect (markerless) from frontal and sagittal views. Joint angles were calculated using two methods: (1) direct kinematics based on body coordinate frames and (2) inverse kinematics using OpenSim's IK tool with anatomical keypoints. Accuracy was evaluated using root mean square error (RMSE) and Bland-Altman analysis. Results indicated that the IK method slightly improved joint angle agreement with OptiTrack for simpler movements, with an average RMSE of 8° for shoulder elevation in the sagittal plane compared to 9° with the coordinate frame method. However, both methods had higher RMSEs for rotational measurements, with IK and coordinate frame methods at 21° for shoulder rotation in the sagittal plane. Forearm pronation-supination measurements were unreliable due to tracking limitations. These findings suggest that Kinect with IK improves accuracy for simpler movements but struggles with rotational joint mechanics. Future research should focus on enhancing markerless tracking algorithms to fully realise the benefits of IK.
No takes yet. Share an insight, caveat, or question.
Scott et al. (2025) studied this question.