This analysis demonstrates preload impacts on force transmission in a piezoelectric actuator system, highlighting significant stiffness improvements.
This article presents a comprehensive investigation of the dynamic coupling between a piezoelectric actuator (PZT) and its driving nonlinear stiffness mechanism (NSM) stage for precise positioning control. Particular emphasis is placed on the preload-induced effects on the force transmission and structural separation between the PZT and NSM. To ensure continuous mechanical contact between them, we propose a no-separation criterion based on acceleration matching, from which the minimum preload requirement is analytically derived. Additionally, static and dynamic simulations reveal that increasing the preload force from 0 N to 10 N can push the first natural frequency of the holistic system from 214.21 Hz to 258.17 Hz, respectively. This beneficially enhances the displacement consistency across different geometric configurations. Moreover, an appropriate preload force can prevent separation and increase system stiffness while reducing nonlinear deformation. Experimental results verifies that a preload of 10 N can prevent the separation between the PZT and NSM stage and maintain achievable output displacement of the stage within the range from 54.35μm to 129.42μm. This article offers the analytical results of preload setting to guarantee reliable actuation for nonlinear precision positioning stages.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: