Experimental analysis reports varying corrosion behavior in X12CrMoWVNbN10-1-1 steel in NaCl solutions, highlighting pH influence.
The influence of pH on the corrosion behavior of X12CrMoWVNbN10-1-1 steel was examined in 0.1 M NaCl solution. The rate of general (uniform) corrosion of the tested steel was determined using linear polarization resistance (LPR) and electrochemical impedance spectroscopy (EIS) methods. In the NaCl solution with a pH of 2.9, the tested steel exhibited a more negative corrosion potential and lower corrosion resistance. Significantly higher corrosion potential and resistance to general corrosion were observed in a neutral solution (pH = 6.5), where the steel was in a passive state.
No takes yet. Share an insight, caveat, or question.
Pejić et al. (2025) studied this question.