Analysis shows boron powder injection reduces radiated power and impurities in plasmas, indicating effective wall conditioning.
Boron powder dropped into KSTAR plasmas decreased the radiated power, core electron density, and Z eff , indicating that the ablated and redeposited boron powder helped to condition the plasma-facing surfaces. Visible line emission of oxygen and tungsten were also reduced by 50% (80%) with boron injection into H-mode (L-mode) discharges that used the new KSTAR tungsten monoblock lower divertor. Dynamic particle balance analysis found a negligible difference in the inferred wall pumping rate during the steady portion of the discharges. It is inferred that the observed conditioning effects were principally caused by a reduction in intrinsic impurities as opposed to a reduction in wall recycling. These results are in qualitative agreement with low- Z injected powder experiments across many fusion devices, confirming the utility of low- Z powder injection as a real-time wall conditioning tool.
No takes yet. Share an insight, caveat, or question.
Schamis et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: