LSPR sensor detects hydrogen sulfide concentrations as low as 0.05 ppm, highlighting enhanced sensitivity with humidity.
A localized surface plasmon resonance (LSPR) sensor for hydrogen sulfide (H 2 S) has been developed by coating a gold nanopattern with zinc oxide (ZnO) film. H 2 S detection was achieved by monitoring changes in absorbance at a specific wavelength in the LSPR spectrum. The absorbance increased during exposure to H 2 S and remained constant after H 2 S ceased. These responses indicate that the sensor can measure the integrated concentrations of H 2 S. The sensitivity to H 2 S was enhanced with increasing relative humidity, enabling detection of 0.05–3 ppm H 2 S within 10 min at 70% relative humidity. The sensor’s sensitivity and LSPR spectrum could be restored by heating it at 500 °C in air. Notably, the sensor did not respond to methyl mercaptan or dimethyl sulfide, demonstrating high selectivity for H 2 S. This study highlights the potential of the ZnO-deposited LSPR sensor for highly sensitive and selective detection of H 2 S.
No takes yet. Share an insight, caveat, or question.
Takimoto et al. (2025) studied this question.