Answers are grounded in this paper and cite their sources.
Case report demonstrates successful tube exchange using balloon enteroscope in altered anatomy, indicating a novel approach.
Scope insertion over an endoscopic nasobiliary drainage (ENBD) tube can facilitate the exchange to internal drainage without the need for selective guidewire reinsertion [1] [2] [3]. During the procedure, an assistant pushes or pulls the ENBD tube to prevent distal migration of the tube tip ([Fig. 1]). However, insertion of a balloon enteroscope over an ENBD tube in patients with surgically altered anatomy is challenging because of the insufficient length of the tube relative to the enteroscope, which precludes positional adjustment by the assistant. Here, we report a case of successful balloon enteroscope insertion over an ENBD tube followed by the exchange of the tube with a plastic stent.
No takes yet. Share an insight, caveat, or question.
Goda et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: