This analysis identifies failure probabilities in the NNBI beam source system, suggesting improvements for plasma heating reliability.
Negative Ion Source Neutral beam Injection (NNBI), as a critical auxiliary heating system for magnetic confinement fusion devices, directly affects the plasma heating efficiency of tokamak devices through the reliability of its beam source system. The single-shot experiment constitutes a significant experimental program for NNBI. This study addresses the frequent equipment failures encountered by the NNBI beam source system during a cycle of experiments, employing fault tree analysis (FTA) to conduct a systematic reliability assessment. Utilizing the AutoFTA 3.9 software platform, a fault tree model of the beam source system was established. Minimal cut set analysis was performed to identify the system’s weak points. The research employed AutoFTA 3.9 for both qualitative analysis and quantitative calculations, obtaining the failure probabilities of critical components. Furthermore, the F-V importance measure and mean time between failures (MTBF) were applied to analyze the system. This provides a theoretical basis and practical engineering guidance for enhancing the operational reliability of the NNBI system. The evaluation methodology developed in this study can be extended and applied to the reliability analysis of other high-power particle acceleration systems.