Key result
Shorter delta F-P timing is linked to successful RVOT ventricular arrhythmia ablation.
Why the study?
Does the delta F-P electrogram index predict successful elimination following a single radiofrequency delivery in patients with idiopathic ventricular arrhythmias?
Observational (n=104)
Does the delta F-P electrogram index predict successful elimination following a single radiofrequency delivery in patients with idiopathic ventricular arrhythmias?
A novel delta F-P electrogram index can predict the successful endocardial ablation of outflow tract ventricular arrhythmias following a single radiofrequency delivery.
Evaluating the peak frequency electrograms has the potential to differentiate near-field from far-field components. This study examined how peak frequency analyses of electrograms preceding idiopathic ventricular arrhythmias (VAs) impact catheter ablation outcomes. A retrospective analysis was conducted on 111 VAs from 104 patients. Electrograms at the earliest activation site, detected using high-density activation maps, were analyzed to assess the association with successful elimination following a single radiofrequency delivery. In outflow tract VAs (n=77), the first deflection timing was similar for VAs with and without successful elimination. The peak frequency timing was earlier (RVOT: -21 ms [-32--16 ms] vs. -11 ms [-20-0 ms], p=0.002, LVOT: -26 ms [-33--4 ms] vs. 0 ms [-6-10 ms], p=0.005) and the difference between the first deflection and peak frequency timing (delta F-P) shorter (RVOT: 7 ms [5-13 ms] vs. 17 ms [11-24 ms], p<0.001, LVOT: 10 ms [6-19 ms] vs. 22 ms [20-27 ms], p=0.001) for VAs with a successful elimination than for those without. The delta F-P correlated with the time to elimination of outflow tract VAs (p=0.01, r= 0.45). None of the outflow tract VAs with delta F-P >22 ms achieved successful elimination. For non-outflow tract VAs (n=34), no parameters were associated with successful elimination. The first component of the EGM at the earliest activation site may reflect a far-field recording from the site of origin of idiopathic VAs. A novel delta F-P electrogram index may predict quick successful endocardial ablation of outflow tract VAs.
No takes yet. Share an insight, caveat, or question.
Nishimura et al. (2025) conducted an observational in Idiopathic ventricular arrhythmias (n=104). Delta F-P electrogram index vs. VAs without successful elimination was evaluated on Difference between first deflection and peak frequency timing (delta F-P) in RVOT VAs (p=<0.001). A shorter difference between the first deflection and peak frequency timing (delta F-P) was associated with successful elimination of RVOT ventricular arrhythmias (7 vs 17 ms, p<0.001).