Key result
Ablation at EGM sites above 325 Hz achieves complete PVC suppression in observed patients.
Why the study?
Does electrogram frequency analysis and isochronal activated surface area mapping predict successful ablation in patients undergoing PVC ablation?
Observational (n=25)
Does electrogram frequency analysis and isochronal activated surface area mapping predict successful ablation in patients undergoing PVC ablation?
Higher electrogram frequency (>325 Hz) and smaller isochronal activated surface area are associated with successful PVC ablation.
May warrant high-frequency electrogram targeting for PVC ablation; extends isochronal mapping but leaves open prospective validation.
Introduction A lower frequency early electrogram (EGM) or broad area of early activation during premature ventricular contraction (PVC) mapping may be associated with a PVC origin in an opposing chamber or deep within the mapped surface. The utility of quantifying EGM frequency at early activation sites and isochronal activated surface area (IASA) is unclear. Our study aimed to investigate the utility of EGM frequency analysis and IASA mapping to complement activation mapping during PVC ablation. Methods High density PVC activation and IASA maps were created using a multi‐electrode mapping catheter in 25 patients undergoing PVC ablation. EGMs in early activation regions were retrospectively studied. IASAs in each mapped chamber were analyzed. Results Ablation success was achieved in 18 of 25 (72%) patients. Ablation was successful in all patients with EGM frequency > 325 Hz (local activation time (LAT) range 28–54 ms) and in all patients with pre‐QRS LAT > 40 ms (EGM frequency range 127–563 Hz). In patients with pre‐QRS LAT < 40 ms and EGM frequency < 325 Hz, ablation was successful in 9 of 16 cases (56%). Mean IASA mapped within 10 ms was smaller at successful ablation sites compared to opposing chambers (0.33 vs 0.95 cm 2 , p = 0.02). All ablation in chambers with IASA > 1.5 cm 2 within 10 ms was unsuccessful. Conclusion Higher EGM frequency and smaller IASA were associated with successful ablation of PVCs. Ablation at sites with EGM frequency > 325 Hz was successful in all patients. The utility of identifying higher frequency EGMs at early activation sites requires further study.
No takes yet. Share an insight, caveat, or question.
Hoffer-Hawlik et al. (2026) conducted an observational in Premature ventricular contractions (n=25). EGM frequency analysis and IASA mapping vs. Opposing chambers / lower frequency sites was evaluated on Mean IASA mapped within 10 ms at successful ablation sites vs opposing chambers (p=0.02). Higher EGM frequency (>325 Hz) and smaller IASA (0.33 vs 0.95 cm2; p=0.02) were associated with successful ablation of premature ventricular contractions.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: