Answers are grounded in this paper and cite their sources.
Technique enables notable lipid suppression in MRSI data, improving metabolite detection for brain studies.
Motivation: MRSI enables mapping of metabolite concentrations throughout the human brain. It is however limited by the contamination of brain spectra due to lipids originating in extracranial adipose tissue. Goal(s): Our goal was to acquire MRSI data with lipid suppressed spectra in the entire brain with a single sequence and the use of spatial priors. Approach: A dual-density k-space trajectory was implemented, enabling the acquisition of a high-resolution spatial prior that was used to remove the lipid contamination from the data, without lengthening the scan time. Results: The resulting MRSI data displayed notable lipid suppression, resulting in metabolite peaks being much more discernible. Impact: A novel acquisition method was developed to simultaneously collect MRSI data and high-resolution spatial priors to suppress spectral lipid contamination. This technique thus has the potential to become a robust clinical tool for studying metabolic changes in the brain.
No takes yet. Share an insight, caveat, or question.
Kadalie et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: