Answers are grounded in this paper and cite their sources.
Automated software pipeline reduces variance in Ktrans values in DCE MRI images, suggesting improved reproducibility in research settings.
Motivation: Processing dynamic contrast-enhanced (DCE) MRI involves several preprocessing steps, making it very time-consuming and challenging to achieve consistency and reproducibility. Goal(s): To develop an automated software pipeline for processing DCE MRI images, enhancing both the speed and consistency of DCE data processing. Approach: We developed a DCE pipeline with preprocessing steps for motion correction, bias field removal, automatic arterial input function (AIF) selection, image alignment, z-slice normalization, segmentation, and quality control report generation. Results: The pipeline successfully processed 400 out of 407 cases, showing significant reductions in population standard deviations for Ktrans values in gray and white matter, and AIF quality scores. Impact: This software will facilitate more reproducible and consistent DCE processing across a variety of imaging sites and research labs.
No takes yet. Share an insight, caveat, or question.
Saca et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: