September 17, 2025Energies2 citationsOpen Access

3D Compressible Flow Analysis of an Ultra-High-Head Pumped Storage Unit with Water Conveyance System at Maximum Pumping Head

View Full Paper
ZLZhixing LiNanchang UniversityXLXinbo LiJilin UniversityXHXingxing HuangCentral China Normal University

Key Points

  • Pressure pulsations were significantly influenced by rotor–stator interactions, creating complex vortical structures.
  • The study found strong bidirectional coupling between flow in the outlet pipe and the pump-turbine unit, indicating critical interaction.
  • Three-dimensional simulations revealed intricate flow characteristics, notably at structures like T-junctions and bifurcations.
  • Analysis demonstrated the importance of examining time-domain and frequency-domain aspects of pressure pulsations in hydraulic components.

Abstract

Severe pressure pulsations caused by complex flow fields in pumped-storage power stations significantly threaten operational safety and stability. With advances in computational technology, fully three-dimensional simulations coupling pipelines and pump-turbine units have become feasible. In this study, a fully three-dimensional analysis model was developed, coupling the water conveyance system and a finely modeled prototype-scale pump-turbine with splitter blades, to numerically simulate the compressible flow field under the maximum head pump mode. The study reveals a strong bidirectional coupling between the flow in the long outlet pipe and the internal flow within the pump-turbine unit. Influenced by structural features such as bifurcations and flow impingement at the T-junction, complex three-dimensional vortices arise and cannot be neglected. Based on the flow field, the study further investigates the time-domain, frequency-domain, and spatial characteristics of pressure pulsations at various downstream hydraulic components, ranging from the vaneless space to the outlet of the long outlet pipe. The pressure pulsation frequencies are shown to be affected by both rotor–stator interactions and the complex vortical structures in the flow. These findings clearly demonstrate the necessity of fully three-dimensional simulations that incorporate both the water conveyance system and the pump-turbine unit.