Synapse
⌘+K
Synapse
PulseExploreClubsResearchersJournals
Instagram
HomeClubsExplore
September 18, 2025Rekayasa SipilOpen Access

Impact of Friction Dampers on Seismic Performance: A Case Study of an Under-Designed Building Subjected to an Earthquake

View Full Paper
Ask AI
Bookmark
Share

Authors

YAYusril AbdurrahmanAWAri WibowoAZAchfas Zacoeb

Discussion

Loading...

Member takes

Overview

Case study analyzes the effects of friction dampers on seismic resilience during earthquake scenarios.

Key Points

  • Adding friction dampers significantly improves a hospital's structural performance during earthquakes.
  • Results indicated an 86.49% reduction in plastic joints in the BSE-2E scenario with dampers added.
  • Nonlinear time history analysis assessed the structural behavior of a five-story reinforced concrete hospital.
  • While effective, dampers had limitations under increased earthquake intensity, requiring further evaluation.

Cite This Study

Abdurrahman et al. (2025) studied this question.

synapsesocial.com/papers/68d462db31b076d99fa62946https://doi.org/10.21776/ub.rekayasasipil.2025.019.03.9
View Full Paper
Ask AI
Bookmark
Share

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1A parametric assessment of seismic behavior of reinforced concrete frames retrofitted using tension-compression resilient slip friction dampers under pulse- and non-pulse like earthquake2025
  2. 2Reduction of Damage Concentration in Seismic Retrofitted RC Building with Friction Dampers2024 · 1 citations
  3. 3Enhancing Seismic Resilience: Evaluating Buildings with Passive Energy Dissipation Strategies2024 · 7 citations
  4. 4An Innovative Retrofitting Technique of an Industrial Prefabricated Building Without Evacuation2024 · 2 citations
  5. 5Seismic Retrofitting of RC Frames Using Viscous Dampers: Numerical Simulation and Nonlinear Response Analysis2025 · 4 citations