Cross-sectional analysis shows significant correlation of saliva with serum urea, creatinine, and amylase levels in chronic kidney disease, indicating potential for noninvasive monitoring.
Introduction: Numerous pathophysiologic mechanisms that result in a persistent decline in glomerular filtration rate are the cause of chronic kidney disease, which results in kidney dysfunctioning. Irreversible kidney dysfunction causes excretory, metabolic, and synthetic failure, which leads to the buildup of nonprotein nitrogenous chemicals and a variety of clinical symptoms. This is the clinical state known as chronic kidney disease. The markers of kidney disease are urea, creatinine and amylase the values of which increase to considerable levels in the serum in azotemic states. As a result, there will be a change in the pH, buffering capacity, rate of salivary flow, and composition of saliva. It necessitates the use of blood sample to assess the renal functional status for multiple times in patients undergoing hemodialysis. Therefore, we aimed to correlate the biochemical parameters of serum and salivary saliva patients receiving hemodialysis for renal failure. Aim: To evaluate the correlation between serum and salivary biochemical parameters, i.e., urea, creatinine and amylase in patients with renal failure before and after hemodialysis. Materials and Methods: The present cross-sectional research was done on 60 subjects with chronic renal failure undergoing Hemodialysis. Subsequently after drawing the blood samples and collection of saliva, they were analyzed for urea, creatinine and amylase levels using a fully automated bioanalyzer. Spearman’s correlation test and Student’s t -test were used to evaluate the correlation between serum and salivary parameters. P <0.05 was considered to be statistically significant. Results: Urea levels in serum and saliva before dialysis were 113.2 and 73, respectively. Mean serum and salivary urea levels after dialysis were 76.8 and 34.5, respectively. Mean serum and salivary creatinine levels before dialysis were 8.86 and 3.3, respectively, whereas the mean serum and salivary creatinine levels after dialysis were 4.2 and 1.8, respectively. Mean serum and salivary amylase levels before dialysis were 104.9 and 37.8, respectively. Mean serum and salivary amylase levels after dialysis were 86.6 and 16.9, respectively. Statistically significant decrease in the parameters after dialysis in both serum and saliva with P = 0.000. A positive significant correlation was seen between all the three parameters between serum and saliva before and after hemodialysis. Conclusion: A significant positive relationship was observed between saliva and serum with respect to urea, creatinine and amylase levels in patients undergoing hemodialysis. Therefore, saliva can be used as a monitoring tool to noninvasively detect the urea, creatinine, and amylase levels, respectively, in renal disease.
No takes yet. Share an insight, caveat, or question.
Adari et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: