Proposed strategies improve traction stability and energy efficiency in distributed electric wheel loaders, indicating promising operational advancements.
In the V-cycle of distributed electric wheel loaders (DEWLs), transport accounts for about 70% of the cycle, making energy saving urgent, while shovel-stage slip limits traction stability. This paper proposes a two-module control framework: (i) a preferred-motor transport strategy that reduces parasitic losses and concentrates operation in high-efficiency regions; and (ii) a load-ratio-based front–rear torque distribution for shoveling that allocates tractive effort according to instantaneous axle vertical loads so that each axle’s torque respects its available adhesion. For observability, we deploy a pre-calibrated lookup-table (LUT) mapping from bucket cylinder pressure to the front-axle load ratio, derived offline from a back-propagation neural network (BP-NN) fit. Tests on a newly developed DEWL show that, compared with dual-motor fixed-ratio control, transport-stage mechanical and electrical power drop by 18–37%, and drive-system efficiency rises by 6–13%. During shoveling, the strategy reduces the peak inter-axle slip from 22–35% to 13–15% and lowers the mean slip to 2.6–5.9%, suppressing sawtooth-like wheel-speed oscillations without sacrificing peak capacity. The method reduces parasitic energy flow, improves traction utilization, and is readily deployable.