Case report presents successful robotic-assisted TAVI in a patient with aortic stenosis, suggesting benefits for radiation exposure.
Background Robotic-assisted transfemoral TAVI remains unreported. We present the first successful case using a novel robotic system. Case Summary A 70-year-old male with severe symptomatic aortic stenosis (mean gradient 52 mmHg, LVEF 48%) underwent robotic-assisted TAVI via femoral access. The procedure was remotely controlled from a radiation-shielded console using a Taurus Elite® 29mm valve. Key steps—wire navigation, balloon valvuloplasty, and valve deployment—were completed robotically in 11 minutes. Post-procedural TTE showed a peak gradient of 12 mmHg and LVEF improvement to 58% at 1 month, with no complications. Discussion This pioneering case confirms the feasibility of robotic TAVI, eliminating operator radiation exposure while maintaining procedural efficacy. The system’s integrated control may standardize complex valve deployments.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: