A replaceable steel energy-dissipating connection is used to realize a reliable connection for precast beam-column joints in assembly substations, and the hysteretic behavior is essential for guaranteeing the seismic performance of the assembly substations. Two types of steel energy-dissipating connections were selected to validate the feasibility of the reliable connection between precast beams and columns within substations. The hysteretic behaviors of the replaceable energy-dissipating connection, including the M - φ characteristics, bearing capacity, stiffness degradation, energy dissipation behavior, and ductility, were investigated. The results demonstrated that the replaceable energy-dissipating connection developed a plumped hysteresis curve, high rotation capacity, excellent energy-dissipation capacity, and good ductility. The plastic damage was concentrated in the weakened flange segment of the steel connection, and the steel connection dissipated more than 70% of the total energy dissipation of the precast beam-column joint. Moreover, the hysteretic behavior of the steel energydissipating connection can easily be restored by replacing the damaged flange segments.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2025) studied this question.