Observational analysis shows strong correlation of CACS across various section thickness and reconstruction parameters, indicating reliable plaque assessment.
Abstract Background: This study aims to investigate the feasibility of coronary artery calcium scoring (CACS) calculating from PureCalcium virtual non-iodine algorithm on photon-counting detector CT (PCD-CT) and the potential impact of different section thickness, level of virtual monoenergetic images (VMIs), and quantum iterative reconstruction (QIR) on the accuracy of CACS quantification. Materials and Methods: A total of 123 patients who underwent coronary CT angiography on PCD-CT with a separate true non-contrast CACS (CACSTNC) scan were prospectively included. Agatston scores were calculated from the PureCalcium algorithm (CACSPC) using a section thickness of 3mm or 1.5mm, different VMI (55–75 kilo-electron volt (keV)) and QIR (strength 1,4) levels, respectively. CACSTNC at 70 keV and QIR 2 were used as reference standards. Differences in CACS of different reconstructions section thicknesses, various keV levels, and QIR strength were compared using the Wilcoxon rank sum test with Bonferroni correction. The intraclass correlation coefficients (ICCs) and Bland-Altman analysis were conducted to assessed the agreement. The agreement of plaque burden groups (based on CACS) at different reconstruction parameters was evaluated using weighted Cohen kappa. Results: At all investigated section thickness, VMI, and QIR levels, the CACSPC were strongly correlated with CACSTNC (ICC: 0.94–0.98, P < 0.001 for all). There were no statistical differences in CACS between CACSPC at 3mm section thickness, 60/65 keV (QIR1/4), and at 1.5 mm section thickness with 55 keV (QIR1/4), compared with CACSTNC. The smallest CACS bias was observed at a 1.5 mm section thickness, 55 keV, QIR 1, with mean bias of 2.4; LoA (IQR: −182.7, 187.4). CACSPC correctly identified 105 of 123 participants (85.4%) into the corresponding plaque burden group using CACSTNCas the referent standard (excellent agreement, κ = 0.904). Conclusion: CACS derived from the PureCalcium algorithm with optimized reconstruction parameters shows excellent correlation with true non-contrast scans derived values. Thus, it is may possible to use the PureCalcium virtual non-iodine algorithm to replace the true non-contrast scans for CACS quantification, without additional radiation dose exposure.
No takes yet. Share an insight, caveat, or question.
Hu et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: