This research demonstrates the efficacy of plasma gasification in reducing volume of simulated radioactive waste, indicating potential for hazardous waste management.
This research demonstrates the high efficiency of thermal plasma gasification for the treatment of simulated operational radioactive waste (SORW), representative of the low-level radioactive waste (LLW) generated in Argentina. A prototype system with a 4.8 kW plasma torch was used to process SORW composed of nitrile gloves, laboratory paper, and stable non-radioactive elements to simulate 60Co, 90Sr, 137Cs, and 144Ce. The process achieved vast volume reduction (99.6%), converting 5625 mL of waste into minimal volumes of four different solid residues (SR): SR1 (20 mL), SR2 (1 mL), SR3 (1 mL), and SR4 (3 mL), resulting in a volume reduction factor (VRF) of 225. Elemental analysis showed clear differences in retention behavior: excellent retention for Co (96 ± 10% inside the plasma reactor) and Ce (59 ± 6%), while more volatile Sr (39 ± 4%) and Cs (26 ± 3%). The latter were partially captured in downstream components (22.8 ± 1.1% Sr and 2.9 ± 0.15% Cs in quencher). The gases treatment system achieved >97% reduction for most plasma generated pollutants: NOx (98.9 ± 0.6%), CO (98.2 ± 0.8%), H2S (97.6 ± 0.6%), and H2 (98.1 ± 0.9%), with 80.6 ± 2.5% for SO2 and 75.0 ± 1.1% reduction for CO2.
No takes yet. Share an insight, caveat, or question.
Pullao et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: