September 26, 2025Magnetic Resonance in Medicine3 citationsOpen Access

Scanner‐based real‐time automated volumetry reporting of the fetus, amniotic fluid, placenta, and umbilical cord for fetal MRI at 0.55T

View Full Paper
SSSara Neves SilvaAUAlena UusHWHadi Waheed

Key Points

  • Automated reporting was achieved for multiple intra-uterine structures, enabling faster assessments.
  • Results showed high accuracy, with scores of 0.98 for fetus, placenta, and amniotic fluid, while umbilical cord scored 0.91.
  • The methodology utilized a multi-region segmentation approach on images from 73 fetal subjects for volumetric measurements.
  • This system supports real-time implementation, providing immediate access to volumetric data during MRI acquisition.

Abstract

Abstract Purpose This work aims to enable real‐time automated intra‐uterine volumetric reporting and fetal weight estimation for fetal MRI, deployed directly on the scanner. Methods A multi‐region segmentation nnUNet was trained on 146 images of 73 fetal subjects (coronal and axial orientations) for the parcellation of the fetal head, fetal body, placenta, amniotic fluid, and umbilical cord from whole uterus bSSFP stacks. A reporting tool was then developed to integrate the segmentation outputs into an automated report, providing volumetric measurements, fetal weight estimations, and z‐score visualizations. The complete pipeline was subsequently deployed on a 0.55T MRI scanner, enabling real‐time inference and fully automated reporting in the duration of the acquisition. Results The segmentation pipeline was quantitatively and retrospectively evaluated on 36 stacks of 18 fetal subjects and demonstrated sufficient performance for all labels, with high scores (0.98) for the fetus, placenta, and amniotic fluid, and 0.91 for the umbilical cord. The prospective evaluation of the scanner deployment step was successfully performed on 50 cases, with the regional volumetric reports available directly on the scanner. Conclusions This work demonstrated the feasibility of multi‐regional intra‐uterine segmentation, fetal weight estimation, and automated reporting in real‐time. This study provides a robust baseline solution for the integration of fully automated scanner‐based measurements into fetal MRI reports.