Answers are grounded in this paper and cite their sources.
This investigation demonstrates improved image quality outcomes in 99mTc imaging, suggesting effective crosstalk compensation using different collimators in radioembolization.
Background 99m Tc-macroaggregated albumin (MAA) imaging is part of the standard work-up procedure for radioembolization using 90 Y microspheres. In certain scenarios, it may be warranted to visualize the distribution of 99m Tc in co-presence of 90 Y, for example when validating intra-procedural 99m Tc-MAA imaging after 90 Y-therapy to enable single-session radioembolization. Another instance involves additional 99m Tc-MAA administration during the therapeutic procedure itself, e.g. when initial imaging reveals insufficient targeting of a specific liver segment. In these situations, crosstalk from 90 Y can result in reduced 99m Tc image quality and quantitative accuracy. This study investigates the feasibility and optimal method of 99m Tc SPECT imaging from combined 99m Tc+ 90 Y data using phantom experiments. Results An anthropomorphic torso phantom with two liver tumor inserts was filled with 99m Tc without (single-isotope) and with 90 Y (dual-isotope) in various activities and isotope concentrations. Three collimators (low energy high resolution: LEHR, medium energy: ME, and high energy: HE) and three methods to compensate for 90 Y crosstalk in the 99m Tc photo peak window (Monte Carlo-based, dual-energy-window and triple-energy-window correction) were evaluated. No substantial dead-time effects were observed in the clinically relevant activity range, up to approximately 12 GBq 99m Tc+ 90 Y (ratio 1:20) with LEHR, 29 GBq with ME and > 30 GBq with HE. Compared to the clinical standard (single-isotope 99m Tc imaging with LEHR collimator), contrast recovery typically decreased from 70.0 ± 1.3% to 49.0 ± 0.9% (LEHR), 61.2 ± 1.5% (ME) or 62.1 ± 1.4% (HE) due to 90 Y crosstalk. Compensation methods increased contrast recovery, with Monte Carlo-based correction combined with a ME or HE collimator yielding the best recovery at 68.5 ± 1.6% and 68.3 ± 1.5%, respectively. Visual image quality in terms of resolution and scatter contamination was superior when using a ME collimator. Lung shunt fractions were also severely affected by 90 Y crosstalk when using LEHR, but could be effectively mitigated using a ME or HE collimator. Conclusion 99m Tc imaging in the presence of 90 Y leads to substantial image degradation due to crosstalk effects. Monte Carlo-based crosstalk compensation in combination with a ME or HE collimator was identified as the most accurate, robust and visually optimal reconstruction method for 99m Tc SPECT from dual-isotope data.
No takes yet. Share an insight, caveat, or question.
Kerckhaert et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: