Investigation reports significant capacity loss in full cells of phosphorus-based sodium-ion batteries, suggesting critical degradation pathways.
Phosphorus-based sodium-ion batteries (SIBs) are promising candidates for next-generation energy storage due to their high theoretical capacity and elemental abundance. However, their long-term degradation behavior remains poorly understood, especially at practical cell capacities. In this work, we systematically investigate a high-capacity 21700-type 3 Ah phosphorus-based SIB using 700-cycle electrochemical evaluation, advanced microstructural analysis, and specific surface area measurements. Strikingly, phosphorus-based anodes exhibit more severe capacity loss in a full cell than a half cell. Furthermore, the formation of (NaxP, x = 1–3) spherical particles on the anode surface is observed for the first time under extended cycling, revealing a key failure pathway. This study provides direct, cycle-scale evidence of the dominant degradation route in practical phosphorus-based SIBs, offering crucial insights for targeted anode material engineering and lifetime enhancement strategies.
No takes yet. Share an insight, caveat, or question.
Yang et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: