This control method enhances harmonics suppression in LCL-type inverters, suggesting improved frequency adaptability.
A novel fractional-order repetitive control based on phase angle information interpolation is proposed for single-phase LCL-type inverters in this paper. Conventional fractional-order repetitive control typically relies on inaccurate grid frequency information detected by a phase-locked loop or the frequency-locked loop, which may result in a potential degradation in harmonics suppression capability. To address this issue, phase information is investigated to implement the fractional order of the repetitive controller through the linear interpolation method. A major advantage of the proposed scheme lies in that it avoids explicit frequency calculation and reduces sensitivity to frequency estimation fluctuations compared with conventional fractional-order repetitive control, enhancing its frequency adaptability. The stability analysis and the design process for the proposed scheme based on a plug-in-type repetitive control are given. Experimental results support the efficacy and advantages of the proposed control strategy.
No takes yet. Share an insight, caveat, or question.
Zhao et al. (2025) studied this question.