September 30, 2025Frontiers in Endocrinology2 citationsOpen Access

LLM evaluation for thyroid nodule assessment: comparing ACR-TIRADS, C-TIRADS, and clinician-AI trust gap

View Full Paper
XDXi DaiYXYu XiYHYong Hu

Key Points

  • GPT-4o achieved the highest predictive AUC of 0.898 under C-TIRADS, indicating strong malignancy risk assessment.
  • Clinicians rated DeepSeek-R1 highest for trust and recommendation quality, especially under the C-TIRADS framework.
  • Both GPT-4o and GPT-o3-mini received lower clinician ratings, highlighting a potential trust gap in AI recommendations.
  • Alignment between AI outputs and clinician expectations is crucial for real-world implementation of LLMs in thyroid management.

Abstract

Objective To evaluate the diagnostic performance and clinical utility of advanced large language models (LLMs) -GPT-4o, GPT-o3-mini, and DeepSeek-R1- in stratifying thyroid nodule malignancy risk and generating guideline-aligned management recommendations based on structured narrative ultrasound descriptions. Methods This diagnostic modeling study evaluated three LLMs—GPT-4o, GPT-o3-mini, and DeepSeek-R1—using standardized narrative ultrasound descriptors. These descriptors were annotated by consensus among three senior board-certified sonologists and processed independently in a stateless manner to ensure unbiased outputs. LLM outputs were assessed under both ACR-TIRADS and C-TIRADS frameworks. Two experienced clinicians (a thyroid surgeon and an endocrinologist) independently rated the outputs across five clinical dimensions using 5-point Likert scales. Primary outcomes included the area under the receiver operating characteristic curve (AUC) for malignancy prediction, and clinician ratings of guideline adherence, patient safety, operational feasibility, clinical applicability, and overall performance. Results GPT-4o achieved the highest predictive AUC (0.898) under C-TIRADS, approaching expert-level accuracy. DeepSeek-R1, particularly with C-TIRADS, received the highest clinician ratings (mean Likert: surgeon 4.65, endocrinologist 4.63), reflecting greater trust in its practical recommendations. Clinicians consistently favored the C-TIRADS framework across all models. GPT-4o and GPT-o3-mini received lower ratings in trustworthiness and recommendation quality, especially from the endocrinologist. Conclusion While GPT-4o demonstrated superior diagnostic accuracy, clinicians most trusted DeepSeek-R1 combined with the C-TIRADS framework for generating practical, guideline-consistent recommendations. The findings highlight the critical need for alignment between AI-generated outputs and clinician expectations, and the importance of incorporating region-specific clinical guidelines (like C-TIRADS) for the effective real-world implementation of LLMs in thyroid nodule management decision support.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Dai et al. (2025) studied this question.

synapsesocial.com/papers/68dc262a8a7d58c25ebb3452https://doi.org/10.3389/fendo.2025.1667809