Answers are grounded in this paper and cite their sources.
Retrospective analysis of 3D models reducing surgical complications in cranio-vertebral junction procedures.
Background: Various Cranio-vertebral junction anomalies are frequent diseases treated by neurosurgeons regularly. This is a region with high variations in anatomy; and a region packed with crucial blood vessels- the vertebral artery and the craniospinal junction which has to be safeguarded during such complex surgery. Despite refinements in surgical technique and expertise, surgery in this region is still fraught with high rates of complications like vertebral artery injuries, screw malposition, failed surgery etc. Lack of a stereoscopic understanding of the highly variable CVJ anatomical relationships is believed to be main reason for these problems. Hence the potential for the 3 dimensional models which give exact understanding and stereoscopic visualisation of the CVJ anatomy on case to case basis to improve outcomes is examined in this study. Objective: Highlight our institutional experience with these 3-dimensional printed models and analyse their benefits in reducing intra-operative complications Materials and Methods: Retrospective study of 65 patients operated for various CV Junction anomalies over the last 3 years. Results: Total number of patients in our study was 65. Of these 37 (62.5%)were males and the rest 28 (37.5%) were females. Atlanto-Axial dislocation was the most common pathology. In this study, we had a low complication rate. There were no cases of screw malposition or vertebral artery injury. We found clinical improvement in 61/65 cases with 03 being the same. On retrospective analysis, higher rate of mortality, vertebral artery injury and screw malpositions (and hence revision surgery) with significant longer operative times were seen in cases without the 3 dimensional models. Conclusion: 3D models replicate the congenital bone and joint defects abnormal lie of vertebral artery hence giving the neurosurgeon the exact intra- operative scenario and boosts his confidence performing the surgery. • It facilitates pre operative planning of screw trajectory and allows real time practice of placing the screws and evaluating the construct. • It has a direct implication in improving the accuracy of instrumentation and prevention of disastrous complication like VA injury. • It will be beneficial to include these models as pre-operative routine workup in CV Junction cases.
No takes yet. Share an insight, caveat, or question.
Panchapakesan et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: