Proposed IC-ELESO improves position estimation in PMSM systems, indicating better control performance.
In sensorless control systems of permanent magnet synchronous motors (PMSMs), the traditional linear extended state observer (LESO) is preferred due to its simplicity and ease of implementation. With the development of PMSM sensorless control systems, the requirements for position estimation performance have increased, and thus, traditional LESOs can no longer meet those needs. To address this issue, this article proposes an estimation method based on an integrally compensated-enhanced linear extended state observer (IC-ELESO) and an improved quadrature phase locked loop (IQPLL) with a third-order LESO. In the back electromotive force estimation scheme, by introducing a compensation loop, the proposed IC-ELESO suppresses DC bias and improves position estimation accuracy compared to traditional LESOs. In the position estimation scheme, the IQPLL combines the third-order LESO with a quadrature phase locked loop (QPLL) to eliminate errors introduced by ramp signals. Finally, a PMSM experimental platform is built to conduct a comparative experiment between the method proposed and the traditional LESO, which verifies the feasibility and superiority of the method proposed in this article.
No takes yet. Share an insight, caveat, or question.
Lin et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: