Comparing PSMA-PET/CT with scintigraphy estimates renal function in prostate cancer patients, suggesting improved efficiency.
Abstract Background: Physiological prostate-specific membrane antigen (PSMA) expression in renal proximal tubules results in radiopharmaceutical uptake in PSMA-PET, suggesting the potential to assess renal function. Thus, we evaluated whether PSMA-PET/CT allowed estimation of split renal function (SRF), potentially replacing [99mTc]Tc-MAG3 scintigraphy. We retrospectively analyzed 302 patients with metastatic castration-resistant prostate cancer undergoing PSMA-PET/CT using either [¹⁸F]F-flotufolastat ([¹⁸F]F-rhPSMA-7.3) (n=221) or [⁶⁸Ga]Ga-PSMA-11 (n=81), along with [99mTc]Tc-MAG3 scintigraphy, prior to PSMA radioligand therapy. SRF was calculated from PSMA-PET/CT using mean standardized uptake values and CT-derived renal volumes. SRF was calculated from [99mTc]Tc-MAG3 using standard integral analysis. Correlations between PET-derived SRF (PET-SRF) and [99mTc]Tc-MAG3 -derived SRF ([99mTc]Tc-MAG3-SRF) were assessed using Pearson correlation and Bland–Altman analysis. Receiver operating characteristic (ROC) analyses were conducted to evaluate diagnostic performance in detecting impaired renal function (SRF ≤ 25% and ≤40%). A PET-based accumulation index (ACI) was explored for correlation with estimated glomerular filtration rate (eGFR). Results: Strong correlations were found between PET-SRF and [99mTc]Tc-MAG3-SRF (r=0.88 for [¹⁸F]F-flotufolastat, r=0.85 for [⁶⁸Ga]Ga-PSMA-11; both p<0.0001). Bland–Altman analysis showed a smaller mean bias and narrower limits of agreement for [¹⁸F]F-flotufolastat(-0.56%; -11.88% to +10.75%) compared with [⁶⁸Ga]Ga-PSMA-11 (-1.18%; -15.3% to +12.95%), with 92% versus 83% of values within ± 10%, respectively. ROC analysis confirmed excellent accuracy for identifying [99mTc]Tc-MAG3-SRF ≤ 25% (area under the curve [AUC] = 0.997 for [¹⁸F]F-flotufolastat; AUC = 0.942 for [⁶⁸Ga]Ga-PSMA-11). ACI and eGFR were not significantly correlated (Spearman’s ρ=0.048; p=0.49]). Conclusion: PSMA-PET/CT provides reliable estimates of SRF, with [¹⁸F]F-flotufolastatshowing slightly superior agreement with [99mTc]Tc-MAG3 scintigraphy. This may potentially eliminate the need for additional renal scintigraphy for SRF assessment in the future and may simplify workflows and reduce patient burden.
No takes yet. Share an insight, caveat, or question.
Gammel et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: