October 2, 2025Journal of Clinical Medicine4 citationsOpen Access

Endoanal Ultrasound in Perianal Crohn’s Disease

View Full Paper
MPMario PaganoFLFrancesco LittaAPAngelo Parello

Key Points

  • Endoanal ultrasound reliably detects fistulas and abscesses, providing high-resolution imaging of the anal sphincter complex.
  • Characteristic features like tract width greater than 4 mm and the Crohn’s Ultrasound Fistula Sign help differentiate Crohn’s-related fistulas from others.
  • Comparative studies show endoanal ultrasound and MRI have similar sensitivity for simple fistulas, while MRI is superior for complex cases.
  • Emerging technologies like elastography may enable future activity scoring mechanisms to improve management in chronic conditions.

Abstract

Background: Perianal Crohn’s disease (pCD) is one of the most disabling complications of inflammatory bowel disease, characterized by fistulas and abscesses that demand precise imaging for diagnosis, treatment planning, and follow-up. Magnetic resonance imaging (MRI) is considered the reference standard, but endoanal ultrasound (EAUS) with high-frequency 360° probes provide a readily available, cost-effective, and repeatable alternative. Methods: We performed a narrative review of the literature, evaluating studies on the EAUS technique, diagnostic applications, distinguishing features of Crohn’s-related fistulas, and comparative analyses with MRI. Consensus documents and structured reporting initiatives were also included. Results: EAUS provides high-resolution visualization of the anal sphincter complex and intersphincteric space, enabling the reliable detection of fistulas and abscesses. Characteristic features such as tract width > 4 mm, bifurcation, hyperechoic debris, the Crohn’s Ultrasound Fistula Sign (CUFS), and the rosary sign assist in differentiating Crohn’s from cryptoglandular fistulas. EAUS is well-suited for serial monitoring, perioperative seton guidance, and therapeutic decision-making. Emerging tools such as Doppler and shear wave elastography provide additional information on activity and fibrosis. MRI remains indispensable for supralevator disease, deep pelvic sepsis, and standardized activity indices. Comparative studies indicate similar sensitivity for simple fistulas, with MRI superior in complex cases; combining both modalities maximizes accuracy. Conclusions: EAUS is a practical and repeatable imaging tool that complements MRI in the multidisciplinary management of perianal Crohn’s disease. Advances such as 3D imaging, contrast enhancement, and elastography may enable validated activity scoring—for example, a future PEACE (Perianal Endosonographic Activity in Chron’s Evaluation) Index—further strengthening its role in longitudinal care.