Experimental validation of a novel vacuum-packed particle damper model highlights tunable performance and efficiency.
In this work, we investigate Vacuum-Packed Particle (VPP) dampers -- granular-core dampers offering tunable damping performance -- as a more sustainable alternative to conventional systems such as magnetorheological fluid dampers. A comprehensive computational model of the entire VPP damper system is developed using the Discrete Element Method (DEM). A novel discrete-element model of the flexible foil, responsible for consistently transmitting the external pressure resulting from vacuum application, is introduced and implemented by extending the open-source Yade DEM framework. A prototype VPP damper is also designed and experimentally tested, enabling both model calibration and validation of the simulation results. The calibrated DEM model is subsequently employed in a parametric study to assess the influence of material, geometrical, and process parameters on damper performance. All code, along with the associated experimental and simulation datasets, is made available in an open-access repository.
No takes yet. Share an insight, caveat, or question.
Chodkiewicz et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: