Assessment reveals iCassette assay sensitivity varies in different matrices, highlighting the need for effective QC products.
Background Illicit fentanyl use is endemic in the United States, yet availability of commercial FDA-approved assays is limited and typically relegated to automated chemistry platforms. Until recently, there were no FDA-approved point of care tests (POCT), despite the extremely common practice of POCT-based drug screening. The Abbott iCassette Fentanyl Urine Drug Screen assay is FDA-approved, CLIA-waived, for the detection of fentanyl in human urine (limit of detection: 1.0 ng/mL); the assay is reported to not detect fentanyl metabolites such as norfentanyl. Unfortunately, a commercial quality control (QC) product is not provided nor recommendations for one given, rather the manufacturer recommends the end user produce their own QC material using certified reference material. As manufacturing one’s own QC material in a setting that requires POCT assays is not generally feasible nor advisable, here we identified an appropriate commercial QC product and subsequently evaluated the assay manufacturer’s sensitivity claims. Methods Thermo Scientific DRI Fentanyl II High and Low Control Set, UTAK Fentanyl Analogs and UTAK Certified Drug Free Urine commercial QC products were evaluated for their ability to reliably produce a positive test result. Cerilliant fentanyl analytical reference standard material (F-013) was spiked into certified drug free urine at various concentrations to investigate the detection limits of the assay. Spiked concentrations were verified by mass spectrometry (LC-MS/MS). Further, the assay sensitivity was challenged with authentic fentanyl-positive urine specimens with known concentrations, as determined by LC-MS/MS. Results The DRI Fentanyl II High Control Set QC material with a claimed fentanyl concentration of 1.5 ng/mL failed to produce a clear positive (test line still visible, interpreted as negative) when dosing 100 µL and 200 µL on the cassette. UTAK Fentanyl Analogues QC material, with a fentanyl concentration of 3.5 ng/mL, reliably produced clear positive results (complete absence of test line). Cerilliant fentanyl standard spiked into drug free urine at 4.5 ng/mL produced a clear positive result while a faint test line was still visible (negative interpretation) at 0.6 ng/mL. Authentic patient urines with known fentanyl concentrations, as determined by LC-MS/MS, were unequivocally positive at fentanyl concentrations of 0.86 ng/mL and greater. An authentic specimen containing 0.05 ng/mL fentanyl produced a very faint test line (negative interpretation). Conclusion The iCassette Fentanyl assay may not produce reliable positive results when using QC material with fentanyl concentrations close to the claimed detection limit of 1.0 ng/mL. However, we found the assay’s sensitivity to be greater in authentic patient specimens versus QC material. This suggests either the assay sensitivity is variable across matrices (i.e. less sensitive in an artificial QC matrix) or the assay detects at least some fentanyl metabolites in addition to fentanyl. Ultimately we concluded that the assay was adequate for clinical use and we implemented with the UTAK material as the positive control.
No takes yet. Share an insight, caveat, or question.
Koch et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: