Evaluation reveals on-board hemolysis enhances G6PD detection efficiency in clinical settings, suggesting better accuracy.
Background G6PD deficiency is an X-linked, hereditary genetic defect caused by mutations in the G6PD gene. It is a common human enzyme defect and is prevalent in some regions of the world. The most common clinical manifestations of G6PD deficiency are neonatal jaundice and acute hemolytic anemia that is often triggered by an exogenous agent. Currently, the mainstream methods for detecting G6PD deficiency are the fluorescent-spot-method and the UV-enzymatic method running on biochemistry analyzers. The fluorescent-spot-method is not able to identify heterozygotes G6PD deficiency, with long test time and low efficiency. Traditional UV-enzymatic method detects G6PD only, requiring pre-manual sample-dilution and treatment to obtain hemolysate. These operations are cumbersome and time-consuming. G6PD mostly resides in red cells. Due to the variation of the red cell quantity in samples, the G6PD deficiency needs to be reported as the ratio of G6PD activity over Hb (U/g). Commonly, the Hb concentration from the same sample is measured separately by a hematology analyzer. The ratio G6PD/Hb (U/g) is then calculated, which is not convenient if there is a large demand for G6PD tests. This study evaluated the performances of a new G6PD assay with enhanced reagent formulation for stability on Mindray BS-600M analyzer having on-board sample hemolysis and twin-chemistries (G6PD and Hb) measured in parallel. The ratio of G6PD/Hb is reported directly by the analyzer. Methods Mindray G6PD assay is a UV-enzymatic method. It is designed with an innovative approach with on-board hemolysis on the BS-600M system, using one method to measure G6PD activity and a 2nd method to measure Hb in parallel to report two results simultaneously and calculated the ratio of G6PD/Hb (U/g). Within 15 min, the ratio results can be obtained, which greatly improves the work efficiency compared with the 1-3h required by the traditional methods. The reagent onboard stability, using two levels of quality controls and serum pools, was conducted with a constant reagent consumption mode to simulate as it is used in clinical labs. Following CLSI protocols, the assay performances were evaluated: method comparison, onboard stability, precision, and linearity. Results On Mindray BS-600M analyzer, our G6PD(U/g) assay correlated well with the results using traditional UV-enzymatic method reagent with manual sample pre-treatment for obtaining hemolysate (Mindray = 1.0191* Manual method-0.0934, r=0.95). Mindray G6PD assay also demonstrated an excellent onboard stability. With uncapped reagent on the system, the reagent stability is for 21 days without recalibration (with less than ± 5% deviation from day zero results). In comparison, a routinely used UV-enzymatic reagent (freeze-dried) from another company showed significant drifting (deviation >±10% vs that on day 0, within 7 days). The repeatability and with-lab CVs of our assay were ranged from 0.40% to 1.86%, respectively. Conclusion On Mindray BS-600M analyzer, the new G6PD assay shown characteristics of the short test time, high efficiency, excellent precision, and good correlation (accuracy). Therefore, we conclude that the new Mindray G6PD assay is suitable for use in routine clinical laboratories where large quantity of the G6PD tests are required.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: