October 4, 2024Cardiology in the Young2 citations

Patent ductus arteriosus closure in small infants weighing less than 1500 g using KA micro plug: steps and tips

View Full Paper
BNBassel Mohammad NijresMHMoeez HassanJWJimmy Winsdor

Key Points

Key points are not available for this paper at this time.

Abstract

Abstract Background: Transcatheter patent ductus arteriosus closure in premature infants is gaining attention with rapidly growing experience. The KA micro plug device poses many favourable features for ductus arteriosus closure in premature infants. The study aimed to describe the technique and outcomes of a KA micro plug in closing the ductus arteriosus in premature infants weighing less than 1500 g. Methods: This is a single-centre retrospective study in premature infants with patent ductus arteriosus weighing less than 1500 g who underwent off-label use of a KA micro plug at the Stead Family Children’s Hospital from February 2022 to December 2023. Results: Eighteen premature infants weighing less than 1500 g underwent attempted transcatheter ductus arteriosus closure using a KA micro plug device. Median weight, age, and corrected gestational age at the procedure were 943 g (682–1225), 26 days (9–79), and 28.5 weeks (25.6–32), respectively. The procedure was successful with complete closure achieved in all patients. No major haemodynamic instabilities were encountered. No catheterization-related complications were encountered. On a median follow-up of 10.9 months (0.1–19), all patients are alive with the device in a good position without residual shunt or abnormal findings. Conclusion: KA micro plug device for patent ductus arteriosus in infants weighing less than 1500 g is feasible, safe, and effective. We recommend that manufacturers of devices used to close the ductus arteriosus in small infants enhance both the devices and their delivery systems to simplify the procedure and mitigate the risk of haemodynamic instability.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Nijres et al. (2024) studied this question.

synapsesocial.com/papers/68e55c8ae2b3180350efa159https://doi.org/10.1017/s1047951124025629
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Institutional Trend in Device Selection for Transcatheter PDA Closure in Premature Infants2022 · 19 citations
  2. 2Patent Ductus Arteriosus: An Overview2007 · 189 citations
  3. 3Initial clinical experience with the Medtronic Micro Vascular Plug™ in transcatheter occlusion of PDAs in extremely premature infants2016 · 94 citations
  4. 4Patent Ductus Arteriosus, Indomethacin and Necrotizing Enterocolitis in Very Low Birth Weight Infants: A Population-Based Study2005 · 254 citations
  5. 5Safety and Short-Term Outcomes for Infants < 2.5 kg Undergoing PDA Device Closure: A C3PO Registry Study2023 · 20 citations