Soft peristaltic pumps, which use soft ring actuators instead of mechanical pistons or rollers, offer advantages in transporting liquids with non-uniform solids, such as slurry, food, and sewage. Recent advances in 3D printing with flexible thermoplastic polyurethane (TPU) present the potential for single-step fabrication of these pumps, distinguished from handcrafted, multistep traditional silicone casting methods. However, because of the relatively high hardness of TPU, TPU-based soft peristaltic pumps contract insufficiently and thus cannot perform as well as silicone-based ones. Improving the performance is crucial for fully automated, one-step manufactured soft pumps to lead to industrial use. This study aims to enhance TPU-based soft pumps through bioinspired design. Specifically, it proposed a design inspired by embryonic tubular hearts, in contrast to previous studies that mimicked digestive tracts. The new design facilitated long-axis stretching of an elliptical lumen during non-concentric contractile motion, akin to embryonic tubular hearts. The design was optimized for ring actuators and pumps 3D-printed with shore hardness 85A TPU filament. The ring actuator achieved over 99% lumen closure with the best designs. The soft pumps transported water at flow rates of up to 218 ml/min and generated a maximum discharge pressure of 355 mmHg, comparable to the performance of blood pumps used in continuous renal replacement therapy.